CAT.IDE.A.240 Supplemental oxygen — non-pressurised aeroplanes
Non-pressurised aeroplanes operated at pressure altitudes above 10000 ft shall be equipped with supplemental oxygen equipment capable of storing and dispensing the oxygen supplies in accordance with Table 1.
Table 1 Oxygen minimum requirements for non-pressurised aeroplanes
Supply for | Duration and cabin pressure altitude |
---|---|
Occupants of flight crew compartment seats on flight crew compartment duty and crew members assisting flight crew in their duties | The entire flying time at pressure altitudes above 10000 ft. |
Required cabin crew members | The entire flying time at pressure altitudes above 13000 ft and for any period exceeding 30 minutes at pressure altitudes above 10000 ft but not exceeding 13000 ft. |
Additional crew members and 100 % of passengers | The entire flying time at pressure altitudes above 13000 ft. |
10 % of passengers
|
The entire flying time after 30 minutes at pressure altitudes above 10000 ft but not exceeding 13000 ft. |